Ericsson Rbs Software Download
RBS/BTS Engineer, T1 tester, Operations & Maintenance Resume keywords summary: ERICSSON RBS 3206/3106 & 2206/2106, T1 TESTER, GSM/EDGE Contact Information Please log in to see the contact information! Work Experience Experience level: 2-5 years Profile/Cover Letter: ROMULO G. 312 Silvertip Ct Milpitas, CA 95035 USA Mobile: +1 408-807-3659 Email: jun_linga@yahoo.com POSITIONS APPLIED FOR: RBS/BTS Engineer, T1 Tester, Cellsite Operations & Maintenance Engineer, Transmission/Microwave Engineer, RF Engineer SUMMARY OF QUALIFICATIONS: Expertise in commissioning, integration, testing, operation & maintenance of Ericsson 2G & 3G Radio Base Stations (RBS 3206/3106, RBS 2206/2106). Expertise in T1/E1 testing. Expertise in commissioning, integration, testing, operation & maintenance of NOKIA & SIEMENS 2G Base Transceiver Stations (SIEMENS BTSE 240XL 850/1900, NOKIA INTRATALK 900/1800, ULTRASITE/EDGE 850/900/1800/1900, INSITE, METROSITE, CONNECSITE, PICOSITE).
Experienced in design, site survey, implementation & operations of Microwave Radio. Expertise in implementation, commissioning, testing, operation & maintenance of Microwave Transmission Network – PDH (NOKIA FLEXIHOPPER, DMC SERIES, ERICSSON MINILINK, SIEMENS SRAL, SIEMENS XD, NERA, HARRIS) – SDH (NERA, SIEMENS MUX, ALCATEL 9600LSY, CADM 1642 MUX). Operation & Maintenance of Base Station Controller (NOKIA BSC 2i & 3i – DX 200). Experience in GSM RF drive testing. Expertise in Outside Plant Engineering which includes FTNN, permitting and F2 conditioning.
Knowledge in FTTP. EDUCATIONAL BACKGROUND: PAMANTASAN NG LUNGSOD NG MAYNILA (University of the City of Manila) Gen. Les Parapluies De Cherbourg Torrent Francais Quebec. Luna St., Intramuros Manila, Philippines Graduation Date: April 1999 • B. In Electronics and Communications Engineering (ECE) WORK EXPERIENCE: ATLAS WIRELESS & TELECOMMUNICATION, INC 9208 Hollyridge Place Tampa, FLORIDA USA 33627 +1 703-608-1315 POSITION: ERICSSON RBS ENGINEER September 2008 – Present Amatel Inc AT&T Oklahoma/Arkansas UMTS 2nd Carrier Project ERICSSON RBS 3206/3106 Install, Commission & Integrate Ericsson Node B RBS 2nd Carrier (3206/3106).
Solucion Jave RBS Element Manager. Download as TXT, PDF, TXT or read online from Scribd. Ericsson RBS Commissioning Guide.
Provides LMC which includes T1 cable line up/termination from RBS to NIU & antenna jumper cable installation from RBS to diplexers. Install 2nd Carrier Add Kit which includes FU, RU, RAX Board, TX Board & ET Board. Load ADD PSU & ADD SECTOR Script files. Integrate site & conduct call testing using LG 3G phone.
Conducts data testing using Sierra Wireless 3G Air Card. Conducts E911 Call Testing (Phase 1 & Phase 2). Provides proper documentations & reports. Conducts site Quality Audit.
Activate ETMC-1 board which includes loading of ETMC-1 Script file. Provides T1 turn-up support which includes T1 troubleshooting/isolation from Node B to NIU. Conducts T1 testing using T-BERD. This includes Head to Head testing from NIU to Switch. AT&T Oklahoma/Arkansas UMTS NB Project ERICSSON RBS 3206/3106 Install, Commission & Integrate Ericsson Node B RBS 3206/3106 (1900& 850).
Provides LMC which includes grounding installation from RBS to MGB, T1 cable line up/termination from RBS to NIU, antenna jumper cable installation from RBS to diplexers, battery wiring installation, AC filter installation, correct ACCU strapping, RBS cabinet power-up & BBU power-up. Load RBS Basic Package, Script Files & RBS Upgrade Package (P6). Integrate site & conduct call testing using LG 3G phone. Conducts data testing using Sierra Wireless 3G Air Card.
Provides proper documentations & reports. Conducts site Quality Audit. Amatel Inc AT&T Oklahoma DOBSON-GSM Swapped Out Project ERICSSON RBS 2206/2106 Install, Commission & Integrate Ericcsson RBS 2206/2106. Provides LMC which includes grounding installation from RBS to MGB, T1 cable line up/termination from RBS to NIU, antenna jumper cable installation, battery wiring installation, AC filter installation, correct ACCU strapping, line up/terminate DC power cable from DCCU to rectifier, RBS cabinet power-up & BBU power-up. Load updated RBS software to Flash Card & download IDB to RBS using Local OMT 35_7. Integrate site & conduct call testing using dummy loads.
Responsible for Cut-over of existing Nortel GSM equipment to new Ericson RBS equipment. Activate new Ericsson RBS equipment & conduct call testing on every sector using Ericsson TEMS phone. Conduct E911 call testing (Phase 0 & Phase 2). Provides proper documentations & reports. Conducts site Quality Audit. VERSACOM LLC 8111 LBJ Freeway Suite 685 Dallas, TEXAS USA 75251 +1 972-479-0202 POSITION: OSP DESIGN ENGINEER April 2007 – September 2008 AT&T San Jose, California Project Light Speed Performs Outside Plant Facility conditioning (F2/secondary OSP cable conditioning) for the implementation of AT&T’s VDSL project. This includes fixing existing outside plant bridge taps and replacing existing OSP terminals as needed using ARES/Work Print, ACE Cost Estimates and JAM.
Performs site survey for Fiber to the Node (FTTN) equipment placement. Site survey includes selection of proposed equipment location; power feed and possible cable route going to existing cross connect cabinets (SAI). Able to interpret Right Of Way documents. Able to interpret/draft hand sketched drawings for proposed VRAD location using AutoCAD 2008. Familiar with 52BP, 52B, 52E and ALP-248C VRAD equipments. Knowledge in FTTP.
T-SYSTEMS, INC Remington Tower Suite 1605 E Skelly Dr Tulsa, OKLAHOMA USA 74135 +1 918-665-8757 POSITION: BTS ENGINEER March 2006 – January 2007 Telecom Network Specialist CINGULAR Wisconsin GSM Swapped Out Project SIEMENS BTSE 240XL 850/1900 Provides installation, commissioning and integration of BTS which includes software upgrade, IDF upload/download and hardware configuration. Conducts call testing. Conducts cut-over of existing NOKIA BTS to new SIEMENS BTS. Conducts T1 testing, isolation and troubleshooting. Conducts quality site audit & generates reports. Performs software upgrade using Siemens LMT BR8. El Bufalo De La Noche Libro Pdf Descargar on this page. 5 COBA/COSA upgrade and hardware testing.
Update IDF files. Familiar with RXAIT kits. Telecom Network Specialist Cingular New Orleans/Baton Rouge, Louisiana GSM Project NOKIA BTS 850/1900 (Ultrasite EDGE) Provides installation, commissioning and integration of BTS which includes: branching table configuration, software download and upload Conducts call testing. Performs TRX expansion/down grade and BTS re-configuration which includes: simple add, complex add and cabinet add.
Conducts T1 testing, isolation and troubleshooting. Generates NOKIA ESF reports.
Familiar with MCPA & Duplexers setup. EXI Parsons CINGULAR Oregon GSM Project NOKIA BTS 850/1900 (Ultrasite EDGE) Provides installation, commissioning and integration of BTS which includes: branching table configuration, software download and upload Conducts call testing. Performs TRX expansion/down grade and BTS re-configuration which includes: simple add, complex add and cabinet add. Conducts T1 testing, isolation and troubleshooting.
Generates NOKIA ESF reports. SMART COMMUNICATIONS INC Smart Tower 6799 Ayala Ave Makati City PHILIPPINES 1226 +63 2 811-0211 POSITION: ENGINEER (Operations & Maintenance) November 2001 – December 2005 NOKIA BTS 900/1800 (Ultrasite/EDGE, Talk Family, Metrosite, Insite, Connectsite) Responsible for the Operation and Maintenance (O&M) of Smart’s cellsites and Transmission network.
Provides installation and commissioning of BTS which includes: antenna and feeder cable sweep test, branching table configuration, software download and upload, integration and acceptance of Nokia Intratalk / Ultrasite EDGE BTS. Performs TRX expansion, down grade, BTS re-configuration, and LAP-D rate upgrade.
Programs HW database for BTS local configuration and create branching table. Provides immediate action for blocked TRX radio providing 99% availability on voice and data channels Conducts test call and traffic monitoring. Prepares BTS checklists report and documentation during site audit. Performs annual and quarterly preventive/corrective maintenance of cellsites. External alarms testing and monitoring.
Troubleshoot, diagnose, and restore network during outage. Conducts quality site audit and acceptance of new cellsites. Conducts RF field measurements/drive testing using TEMS Investigation & Agilent equipment. Conducts in-building testing/measurements of RF coverage and Service quality (hotels, malls, schools & corporate buildings) to determine areas that need improvement and optimization.
Transmission facilities / BSC and Leased Line Services Conducts site survey & design of Microwave Link Budget using Pathloss. Provides installation and commissioning of different microwave PDH radios (NOKIA FLEXIHOPPER, ERICSSON MINI-LINK, SIEMENS SRA-L and XD, DMC SERIES, NERA), which includes: software downloads and uploads. Conducts 24-hour E1 BER testing using WANDEL & GOLTERMANN E1/T1 TESTER.
Conducts E1/T1 isolation and troubleshooting. Operation and Maintenance of NERA SDH radios and SIEMENS MUX. Provides 100% radio link connectivity, BER testing, and fault isolation up to BSC side. Provides Operations and Maintenance in Transmission Monitoring Center. Performs immediate action for restoration of Spur Links, Wire transmissions and Fiber Optics facility.
Provides cross-connections, circuit modification order request, and CAO (Circuit Authorization Order) implementation. Conducts BSC (NOKIA BSC 3i) monitoring, ET activation and rehoming. ATER, Signalling Link and Gb Link expansion and testing. Power Equipment Facilities Installation and maintenance of various AC to DC Telecommunications Power Equipments. Installation of Ericsson AC Filter (ACPI). Responsible for Battery Swapping (Conversion of 2 banks 24Vdc from RBS Ericsson rectifier to 48Vdc and transferring it to NOKIA PSSS/EMPOWER rectifier of GSM 900/1800. Familiar with Hawker, Marathon, Old Ham, and Varta Batteries Familiar with Denyo, DMT, Onan Cummins, FG Wilson, Airman, and Olympian Generators.
Upgrade of transmission rectifier from ATT rectifier to Twin Pack PS19. EXAMINATION(S) TAKEN ECE Professional Licensure Examination November 1999/PASSED SEMINARS/TRAININGS ATTENDED Basic OSP Training (FTTN/VRAD & FTTP) Versacom LLC San Jose, California March 12 – April 06, 2007 Ultrasite Operations Training Smart Communication Inc. September 01-02, 2004 Advance Radio Network Optimization Smart Communication Inc. August 25-27, 2004 Andrew Institute Hands-On Connector Attachment Training Andrew Institute Philippines August 20, 2004 Cross Trainings (Smart Communication Inc.) •Transmission Planning & Engineering July 19, 2004 – August 06, 2004 •RF/Access Planning & Engineering August 09 – August 24, 2004 •Optimization August 30, 2004 – September 10, 2004 GSM RF Repeater (HUTECH 21) - Installation, Commissioning, Troubleshooting and Maintenance KISKO Inc. April 16, 2004 BSSPAR Smart Communications Inc. October 6-7, 2003 Metrosite Installation & Commissioning Smart Communications Inc.
April 17-19, 2002 Cadetship Engineering Program (CEP) Batch VI Smart Communications Inc.
Ericsson Rbs 6201 commisioning (1) • 1. Commissioning Procedure RBS 6201 2G • Requirements Note: • We will require OMT R41H for configuration of 2G part of 6201. • BTS sw will be GSM- BTS_SW_G11A_R29E_(OMT_FORMAT) • BSC sw will be GSM- BTS_SW_G11A_R29E_(BSC-FORMAT) • EC Bus Termination OMT Login Port E1 Interface Incoming power to DUG from PDU • PIN Configuration • Console Cable • AT RJ 45 end--- 123 • AT 9 PIN connector--- 532 • Go to create IDB then select the cabinet type as 6201 RUG, power system as -48 V Dc & cabinet system as Extended because in combo there are 4 no of Fans. • Define the sector as below, same as 2964 • Select the configuration • Select all parameter then Tick mark on RBS configuration wizard click ok • Shelf definitions at 6201 Shelf “F1” Shelf “E1” Shelf “D1” Shelf “C1” Shelf “B1” • Now in configuration wizard define RU position. In this window we can define DUG,RUG,PDU shelf & slot position.
In the beginning it will b shows as undefined • For 2G all RUs (DUG & RUG) shelves are define as C1/E1and corresponding slots are define as above i.e.(1,3,5,7,9,11,13) For the PDU s shelves are define as F1,D1,B1 & respective slots will be 1. • Define HUB Position as B1 then click OK • Define Feeder Loss in dB for all the sectors as per requirement • Define Delay for all the sectors as per requirement • Define PCM same as 2964, sand alone/cascade as per the site status • Define Tie (Mandatory) • This is same as 2964 External alarm definition window. Define it and then click ok • Click on YES • Define power as default, as below. Then click ok and install IDB. • After click on install IDB if wrong RBS operational sate is shown then u should change RBS state in local mode softly (go to cabinet –right click on DUG-change maintenance state) then u observe a blue LED IS FLASING in DUG i.e. It is in local mode. • As describe in previous slide.
Then click on the install IDB icon and go for the process. After complete IDB installation change DUG maintenance state in REMOTE & physically the BLUE LED is OFF.
Then go to Define Present RUS make PDU2 as not present. • Thank You By: Ranjan kak.